9 8. Temperature Function (Fahrenheit): Measures tempera-ture in °F. Auto-ranging from -58°F to +752°F. (Optional “K-Type” thermocouple require

Seite 3 - INTRODUCTION

10 25. 15A Input Jack. For red test lead probe connection when measuring high DC current (up to 15 amps only). 26. DWELL ANGLE, MS °C, °F, BAT

Seite 4 - SPECIFICATIONS

11 1. Plug the BLACK test lead into "COM" jack of the tester; plug the RED test lead into the "V" jack. NOTE: If alligator c

Seite 5

12 NOTE: A diode is a semiconductor device that lets current flow in one direction only. If the diode to be tested is part of a circuit (with ot

Seite 6

13 E. FREQUENCY MEASUREMENT Frequency is the number of times that an event repeats itself during a one-second time period. Frequency is measured

Seite 7

14 H. TEMPERATURE MEASUREMENT WARNING To avoid fire and/or electrical shock hazards, DO NOT connect the thermocouples to circuits greater than

Seite 8

15  To measure from 0 to 400mA, set the Selector Switch to .  To measure from 400mA to 15 Amps DC, set the Selector Switch to the "15A&q

Seite 9 - CONTROLS AND INDICATORS

16 WARNING Ignition coils produce a very high voltage. To reduce the risk of electric shock when conducting RPM tests, DO NOT touch the uninsul

Seite 10

17 Do not apply around or remove from Hazardous Live conductors. 1. Turn the ignition off. DO NOT CONNECT THE INDUCTIVE PICKUP WITH THE ENGINE

Seite 11 - TESTING PROCEDURES

18 2. Press the HOLD button again to turn the function “off.” The HOLD icon will disappear, and the value will no longer be “locked” in the dis

Seite 12

1 Table of Contents Title Page No. INTRODUCTION ... 2 SAFETY PRECAUTIONS/WARNING

Seite 13

19  For battery replacement: Remove one screw from the battery compartment cover. Use your finger or a small coin to remove the cover. Remove t

Seite 16

22 LIMITED ONE YEAR WARRANTY The Manufacturer warrants to the original purchaser that this unit is free of defects in materials and workmanship

Seite 18 - AUXILIARY FUNCTIONS

2 INTRODUCTION  Congratulations. You have purchased a precision instrument manufactured to the highest quality standards. This Digital Automot

Seite 19 - BATTERY AND FUSE REPLACEMENT

3  Always inspect the tester, test leads and any other acces-sories for damage prior to every use. If any damage is found, do not use tester un

Seite 20 - MAINTENANCE

4  Automatic zero adjustment  Over range indicator (except 15 A function). Displays "OL" on LCD  Low battery indicator. Displays

Seite 21

5 ACV TRMS [1] NOTE: Specifications are AC-coupled true RMS. Range Resolution Accuracy Overload Protection 400mV 100μV ±(1.2% of reading +8 digi

Seite 22

6 DC CURRENT (AMPS) Range Resolution Accuracy Overload Protection 40mA 10μA 400mA 100μA ±(1.5% of reading +5 digits) 0.5A/250V fast fuse Input

Seite 23 - REPLACEMENT PARTS

7 TEMPERATURE Range Accuracy Overload Protection 32°F to 104°F (0°C to 40°C) ±5°F/±3°C -58°F to 392°F (-50°C to 200°C) 392°F to 752°F (200°C to 4

Seite 24

8 WARNING Risk of Explosion. This equipment has internal arcing and sparking parts, which should not be exposed to flammable vapors. This equip